Apollo Common Mechanical & Electrical Issues

1. Charge Port Sparking:

Replace worn 3-pin charging socket port and always attach protective rubber cap when riding.

2. Variable E-Brake Cutout Calibration:

Recalibrate regen brake paddle hall sensor voltage in Apollo App menu if false brake cutouts occur.

3. Stem Latch Collar Play:

Tighten secondary safety collar ring to remove handlebar play.